Qty
Vortex flow meter; Operating voltage [V] : 8…33 DC; Min. insulation resistance [MΩ] : 100; (500 V DC); Protection class : III; Power-on delay time [s] : < 2; Total number of outputs : 1; Output signal : analogue signal; Number of analogue outputs : 1; Analogue current output [mA] : 4…20; (water: Q [l/min] = 2,0 x (I – 4 mA); water-glycol: Q [l/min] = 2,0 x (I – 4 mA) – Qo see Figure 2); Max. load [Ω] : 5.5 to avoid cavitation; Materials : PA 6T; Materials (wetted parts) : ETFE; PA 6T; FKM; Tightening torque [Nm] : 12; Process connection : threaded connection G 3/4 DN10
ConnectionConnector: 1 x M12; Contacts: gold-plated
No. of inputs/outputsNumber of analogue outputs: 1
Current consumption< 30 mA
Voltage supply24 V
DisplayDisplay unit: 6 x LED, green (l/min, mu00b3/h, gpm, gph, u00b0C, u00b0F) | measured values: alphanumeric display, 4-digit | programming: alphanumeric display, 4-digit
Degree of protectionIP 65
Weight87.8 g
Dimensions104.5 x 32.5 x 113.6 mm

Downloads

PDF
IFM SV5050 Datasheet PDF
Download