Phoenix Contact
>
Measurement and control technology
>
Signal conditioners
>
Signal conditioners with functional safety
>
Phoenix Contact – MACX MCR-SL-RTD-I-SP-NC
Phoenix Contact – MACX MCR-SL-RTD-I-SP-NC
SIGNAL CONDITIONERS
⍾
Phoenix Contact – MACX MCR-SL-RTD-I-SP-NC
Add to RFQ
Qty
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
>15
Temperature measuring transducer – MACX MCR-SL-RTD-I-SP-NC – 2924320; Temperature transducer, converts signals from resistance thermometers and resistors into 0/4 – 20 mA signals. Freely programmable, 3-way electrical isolation.
Nominal supply voltage
24 Vu00a0DC
Load/output load current output
u2264 500 u03a9
Degree of protection
IP20 (not assessed by UL)
Ambient temperature (operation)
-20 u00b0C ... 60 u00b0C (Any mounting position)
EAN
4046356503884
Browse SIGNAL CONDITIONERS WITH FUNCTIONAL SAFETY catalog
Downloads
Phoenix Contact 2924320 Datasheet PDF (pl)
Download
Phoenix Contact 2924320 Datasheet PDF (de)
Download
Phoenix Contact 2924320 Datasheet PDF (en)
Download
Related in
Signal conditioners with functional safety
⍾ Page 1
« Prev page
Next page »
Product details
Add to RFQ
MACX MCR-SL-RPSSI-2I-SP - Phoenix Contact
Repeater power supply - MACX MCR-SL-RPSSI-2I-SP - 2924838; Measuring transducer repeater power supply and input signal conditioner, HART-transparent. Transmits supplied or active 0/4…20 mA electrically isolated signals from the field to two loads. 4-way electrical isolation, Push-in connection, SIL, PL.
Product details
Add to RFQ
MACX MCR-CJC - Phoenix Contact
Plug - MACX MCR-CJC - 2924993; Plug for cold junction compensation for thermocouples, for safe switching of limit values, in combination with MACX ...-T-UI... temperature transducers.
Product details
Add to RFQ
MACX MCR-SL-NAM-2RO-SP - Phoenix Contact
Isolation amplifier - MACX MCR-SL-NAM-2RO-SP - 2924265; NAMUR signal conditioner for operating proximity sensors and switches. The signals are transferred to the control level using 2 isolated relay outputs (N/O contact). Line fault detection (LFD), 3-way electrical isolation, SIL 2, Push-in connection.
Product details
Add to RFQ
MACX MCR-SL-NAM-R-SP - Phoenix Contact
Isolation amplifier - MACX MCR-SL-NAM-R-SP - 2924252; NAMUR isolation amplifier for operating proximity sensors and switches. The signals are transferred to the control level using relay output (PDT). Line fault detection (LFD), galvanic 3-way isolation, SIL 2, with push-in connection.
Product details
Add to RFQ
MACX MCR-SL-2NAM-T-SP - Phoenix Contact
Isolation amplifier - MACX MCR-SL-2NAM-T-SP - 2924281; NAMUR 2-channel signal conditioner for operating proximity sensors and switches. The signals are transmitted to the control level via transistor outputs (passive). Line fault detection, 3-way electrical isolation, SIL 2, Push-in connection.
Product details
Add to RFQ
MACX MCR-SL-RPSSI-2I - Phoenix Contact
Repeater power supply - MACX MCR-SL-RPSSI-2I - 2924825; Measuring transducer repeater power supply and input signal conditioner, HART-transparent. Transmits supplied or active 0/4…20 mA electrically isolated signals from the field to two loads. 4-way electrical isolation, screw connection, SIL, PL.
Product details
Add to RFQ
MACX MCR-SL-NAM-2T-SP - Phoenix Contact
Isolation amplifier - MACX MCR-SL-NAM-2T-SP - 2924278; NAMUR signal conditioner for operating proximity sensors and switches. The signals are transmitted to the control level via 2 transistor outputs (passive). Line fault detection, 3-way electrical isolation, SIL 2, Push-in connection.
Product details
Add to RFQ
MACX MCR-SL-TC-I-NC - Phoenix Contact
Temperature measuring transducer - MACX MCR-SL-TC-I-NC - 2924346; Temperature transducer, converts signals from thermocouples and linear mV sources into 0/4-20 mA signals. Freely programmable, 3-way electrical isolation, custom-configured.
Product details
Add to RFQ
MACX MCR-SL-2NAM-RO-SP - Phoenix Contact
Isolation amplifier - MACX MCR-SL-2NAM-RO-SP - 2924294; NAMUR 2-channel signal conditioner for operating proximity sensors and switches. The signals are transferred to the control level using relay outputs (N/O contact). Line fault detection, 3-way electrical isolation, SIL 2, Push-in connection.
Product details
Add to RFQ
MACX MCR-SL-2NAM-R-UP-SP - Phoenix Contact
Isolation amplifier - MACX MCR-SL-2NAM-R-UP-SP - 2924304; 2-channel NAMUR signal conditioner with wide range power supply for proximity sensors and switches. In terms of signal output, for each channel there is a relay with a changeover contact available. Line fault detection (LFD), 3-way isolation, Push-in connection, SIL 2.
Product details
Add to RFQ
MACX MCR-SL-RPSSI-I-SP - Phoenix Contact
Power/input isolating amplifier - MACX MCR-SL-RPSSI-I-SP - 2924207; Repeater power supply and input isolating amplifier, HART. Transfers supplied or active 0/4 - 20 mA signals to a load (active or passive). 3-way electrical isolation, SIL 2 according to IEC 61508.
Product details
Add to RFQ
MACX MCR-PTB-SP - Phoenix Contact
Power and error message module - MACX MCR-PTB-SP - 2924184; Power and fault signaling module with Push-in connection, including corresponding ME 17,5 TBUS 1,5/ 5-ST-3,81 GY DIN rail connector