Skip to content
About Us
Select Brand
ABB
Schneider
Phoneix Contact
Siemens
Innomotics
Weidmuller
Gewiss
Fluke
SICK
Baumer
Dungs
Krom schroder
Festo
Norgren
Foxboro
Telemecanique
IFM
Pilz
Contact Us
English
English
Español
Deutsch
Polski
About Us
Select Brand
ABB
Schneider
Phoneix Contact
Siemens
Innomotics
Weidmuller
Gewiss
Fluke
SICK
Baumer
Dungs
Krom schroder
Festo
Norgren
Foxboro
Telemecanique
IFM
Pilz
Contact Us
English
English
Español
Deutsch
Polski
RFQ
Catalog
>
Phoenix Contact
>
Measurement and control technology
>
Signal conditioners
>
Signal conditioners with functional safety
>
Phoenix Contact – MACX MCR-SL-RTD-I-SP-NC
Phoenix Contact – MACX MCR-SL-RTD-I-SP-NC
SIGNAL CONDITIONERS
⍾
Phoenix Contact – MACX MCR-SL-RTD-I-SP-NC
Add to RFQ
Qty
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
>15
Temperature measuring transducer – MACX MCR-SL-RTD-I-SP-NC – 2924320; Temperature transducer, converts signals from resistance thermometers and resistors into 0/4 – 20 mA signals. Freely programmable, 3-way electrical isolation.
Nominal supply voltage
24 Vu00a0DC
Load/output load current output
u2264 500 u03a9
Degree of protection
IP20 (not assessed by UL)
Ambient temperature (operation)
-20 u00b0C ... 60 u00b0C (Any mounting position)
EAN
4046356503884
Browse SIGNAL CONDITIONERS WITH FUNCTIONAL SAFETY catalog
Downloads
Phoenix Contact 2924320 Datasheet PDF (pl)
Download
Phoenix Contact 2924320 Datasheet PDF (de)
Download
Phoenix Contact 2924320 Datasheet PDF (en)
Download
Related in
Signal conditioners with functional safety
⍾ Page 2
« Prev page
Next page »
Product details
Add to RFQ
MACX MCR-SL-RPSSI-I-UP-SP - Phoenix Contact
Repeater power supply - MACX MCR-SL-RPSSI-I-UP-SP - 2924210; Repeater power supply for supplying 2 and 3-conductor transmitters with HART transmission and wide range power supply, SIL, Push-in connection
Product details
Add to RFQ
MACX MCR-SL-IDSI-I-SP - Phoenix Contact
Output signal conditioner - MACX MCR-SL-IDSI-I-SP - 2924223; Output signal conditioner, HART. Isolates and transmits 0/4-20 mA signals to a load (I/P converters, control valves, displays). Electrical 3-way isolation, wire break recognition, SIL 2 in accordance with IEC 61508, Push-in connection.
Product details
Add to RFQ
MACX MCR-SL-I-I-HV-ILP - Phoenix Contact
Loop-powered isolators - MACX MCR-SL-I-I-HV-ILP - 2907704; Single-channel input loop-powered 2-way isolator with increased cut-off voltage and plug-in connection technology for the electrical isolation of analog signals. Input signal = output signal: 0(4) mA ... 20 mA. Screw connection technology.
Product details
Add to RFQ
MACX MCR-SL-I-I-HV-ILP-SP - Phoenix Contact
Loop-powered isolators - MACX MCR-SL-I-I-HV-ILP-SP - 2907705; Single-channel input loop-powered 2-way isolator with increased cut-off voltage and plug-in connection technology for the electrical isolation of analog signals. Input signal = output signal: 0(4) mA ... 20 mA. Push-in connection technology.
Product details
Add to RFQ
MACX MCR-SL-2I-2I-HV-ILP-SP - Phoenix Contact
Loop-powered isolators - MACX MCR-SL-2I-2I-HV-ILP-SP - 2907707; Two-channel input loop-powered 2-way isolator with increased cut-off voltage and plug-in connection technology for the electrical isolation of analog signals. Input signal = output signal: 0(4) mA ... 20 mA. Push-in connection technology.
Product details
Add to RFQ
MACX MCR-SL-2I-2I-HV-ILP - Phoenix Contact
Loop-powered isolators - MACX MCR-SL-2I-2I-HV-ILP - 2907706; Two-channel input loop-powered 2-way isolator with increased cut-off voltage and plug-in connection technology for the electrical isolation of analog signals. Input signal = output signal: 0(4) mA ... 20 mA. Screw connection technology
Product details
Add to RFQ
MACX MCR-SL-UI-REL - Phoenix Contact
Limit value switches - MACX MCR-SL-UI-REL - 2906169; Limit value switch with input for active current and voltage signals and a limit-value relay output (changeover contact). Can be set via DIP switch and potentiometer, galvanic 3-way electrical isolation, up to SIL2 (SC3), PLc Cat.1, screw connection.
Product details
Add to RFQ
MACX MCR-SL-UI-REL-SP - Phoenix Contact
Limit value switches - MACX MCR-SL-UI-REL-SP - 2906170; Limit value switch with input for active current and voltage signals and a limit-value relay output (changeover contact). Can be set via DIP switch and potentiometer, galvanic 3-way electrical isolation, up to SIL2 (SC3), PLc Cat.1, Push-in connection.
Product details
Add to RFQ
MACX MCR-I20 - Phoenix Contact
Plug - MACX MCR-I20 - 2905680; Connection terminal block for current signals, +20 mA ... -20 mA, for safe switching of limit values, in combination with MACX ...-T-UI... temperature transducers.
Product details
Add to RFQ
MACX MCR-SL-2I-2I-ILP-SP - Phoenix Contact
Loop-powered isolators - MACX MCR-SL-2I-2I-ILP-SP - 2905281; Two-channel input loop-powered 2-way isolator with plug-in connection technology for the electrical isolation of analog signals. Input signal = output signal: 0(4) mA ... 20 mA. Push-in connection technology.
Product details
Add to RFQ
MACX MCR-SL-2I-2I-ILP - Phoenix Contact
Loop-powered isolators - MACX MCR-SL-2I-2I-ILP - 2905280; Two-channel input loop-powered 2-way isolator with plug-in connection technology for the electrical isolation of analog signals. Input signal = output signal: 0(4) mA ... 20 mA. Screw connection technology.
Product details
Add to RFQ
MACX MCR-SL-I-I-ILP - Phoenix Contact
Loop-powered isolators - MACX MCR-SL-I-I-ILP - 2905278; Single-channel input loop-powered 2-way isolator with plug-in connection technology for the electrical isolation of analog signals. Input signal = output signal: 0(4) mA ... 20 mA. Screw connection technology.
« Prev page
Next page »