[siemens_summary]
[catalog_children]
[catalog_search_products]

Continuous gas analyzers ⍾ Page 48

Product detailsAdd to RFQ
7MB2111-0EP00-1AA1 - Siemens
ULTRAMAT 6 Field device gas analyzer, for installation in the field, single-channel, 1 component Ferrule screw connection for pipe, outer diameter 6mm C2H2 Smallest measuring range: 0 to 1 %, largest measuring range: 0 to 10 % Internal gas path: hose made of FKM (Viton), sample chamber (lining): Aluminium, reference chamber (flow-type): non-flow-type Without 200 to 240 V AC, 48...
Product detailsAdd to RFQ
7MB2111-0NU00-1AA1 - Siemens
ULTRAMAT 6 Field device gas analyzer, for installation in the field, single-channel, 1 component Ferrule screw connection for pipe, outer diameter 6mm SO2 (TÜV) Smallest measuring range: 0 to 10 %, largest measuring range: 0 to 30 % Internal gas path: hose made of FKM (Viton), sample chamber (lining): Aluminium, reference chamber (flow-type): non-flow-type Without 200 to 240 V AC,...
Product detailsAdd to RFQ
7MB2111-0AB61-1AA1 - Siemens
ULTRAMAT 6 Field device gas analyzer, for installation in the field, single-channel, 1 component Ferrule screw connection for pipe, outer diameter 6mm CO Smallest measuring range: 0 to 10 vpm, largest measuring range: 0 to 200 vpm Internal gas path: stainless steel pipe (mat. no. 1.4571), sample chamber (lining): Aluminium, reference chamber (flow-type): non-flow-type AUTOCAL function with 8 additional digital...
Product detailsAdd to RFQ
7MB2111-0CH00-1AA1 - Siemens
ULTRAMAT 6F GAS ANALYSATOR FOR FIELD MOUNTING GAS CONNECTIONS: SCREWED GLAND FOR STUB 6 MM OD MEASURED COMPONENT: CO2 SMALLEST MEASURING RANGE: 0 TO 1000 VPM LARGEST MEASURING RANGE: 0 TO 10000 VPM INTERNAL GAS PATH: VITON-TUBING SAMPLE CELL (LINING): ALUMINIUM REFERENCE PART OF MEAS.CHAMBER: NON-FLOWING-REFENENCE-SIDE WITHOUT ADDITIONAL ELECTRONICS POWER SUPPLY: AC 220V TO 240V; 48 TO 63 HZ WITHOUT...
Product detailsAdd to RFQ
7MB2111-0AB00-1AA4 - Siemens
ULTRAMAT 6 Field device gas analyzer, for installation in the field, single-channel, 1 component Ferrule screw connection for pipe, outer diameter 6mm CO Smallest measuring range: 0 to 10 vpm, largest measuring range: 0 to 200 vpm Internal gas path: hose made of FKM (Viton), sample chamber (lining): Aluminium, reference chamber (flow-type): non-flow-type Without 200 to 240 V AC, 48...
Product detailsAdd to RFQ
7MB2111-0FV60-7AA1-Z E74 - Siemens
ULTRAMAT 6 Field device gas analyzer, for installation in the field, single-channel, 1 component Ferrule screw connection for pipe, outer diameter 6mm C2H4 Smallest measuring range: 0 to 10 %, largest measuring range: 0 to 100 % Internal gas path: stainless steel pipe (mat. no. 1.4571), sample chamber (lining): Aluminium, reference chamber (flow-type): non-flow-type Without 200 V to 240 V...
Product detailsAdd to RFQ
7MB2041-1DA10-1AA1 - Siemens
Gas Analyzer OXYMAT 64, 19" unit for installation in cabinets ZrO2: Catalytically inactive cell (CIC) Low pressure, without suction pump (Atmosphere) Input: clamping ring connection 6 mm, output: Fittings 6 mm Gas monitoring: Flowmeter and limit switch (internal) Without AC 200 to 240 V, 48 to 63 Hz Without . English
Product detailsAdd to RFQ
7MB2041-3CA11-1AA1 - Siemens
Gas Analyzer OXYMAT 64, 19" unit for installation in cabinets ZrO2: Catalytically inactive cell (CIC); with differential pressure sensor Low pressure, with pump (Atmosphere) Input: clamping ring connection 6 mm, output: Fittings 6 mm Gas monitoring: Flowmeter and limit switch (internal) AUTOCAL function with 8 additional digital inputs and outputs AC 200 to 240 V, 48 to 63 Hz Without...
Product detailsAdd to RFQ
7MB2111-0DM60-1AA1-Z E74 - Siemens
ULTRAMAT 6 Field device gas analyzer, for installation in the field, single-channel, 1 component Ferrule screw connection for pipe, outer diameter 6mm CH4 Smallest measuring range: 0 to 5000 vpm, largest measuring range: 0 to 50000 vpm Internal gas path: stainless steel pipe (mat. no. 1.4571), sample chamber (lining): Aluminium, reference chamber (flow-type): non-flow-type Without 200 to 240 V AC,...
Product detailsAdd to RFQ
7MB2111-0CA00-1AA1 - Siemens
ULTRAMAT 6 Field device gas analyzer, for installation in the field, single-channel, 1 component Ferrule screw connection for pipe, outer diameter 6mm CO2 Smallest measuring range: 0 to 5 vpm, largest measuring range: 0 to 100 vpm Internal gas path: hose made of FKM (Viton), sample chamber (lining): Aluminium, reference chamber (flow-type): non-flow-type Without 200 to 240 V AC, 48...
Product detailsAdd to RFQ
7MB2041-1BB10-1AA0 - Siemens
GAS ANALYZER OXYMAT 64, 19" UNIT FOR INSTALLATION IN CABINETS SENSOR: ZRO2: CATALYTIC INACTIVE CELL (KIZ) PRESSURE OF THE MEASURING GAS: HIGH PRESSURE, WITH PRESSURE CONTROLER 2000 HPA TO 6000 HPA GAS CONNECTIONS: INLET: CLAMPING RING CONNECTION 1/8" OUTLET: STUB 1/4" GAS MONITORING: FLOWMETER AND LIMIT SWITCH (INTERNAL) WITHOUT ADDITIONAL ELECTRONICS POWER SUPPLY: AC 200 V TO 240 V, 47...
Product detailsAdd to RFQ
7MB2041-1DA17-1AA1 - Siemens
Gas Analyzer OXYMAT 64, 19" unit for installation in cabinets ZrO2: Catalytically inactive cell (CIC) Low pressure, without suction pump (Atmosphere) Input: clamping ring connection 6 mm, output: Fittings 6 mm Gas monitoring: Flowmeter and limit switch (internal) AUTOCAL function with 8 additional digital inputs/outputs and PROFIBUS DP interface AC 200 to 240 V, 48 to 63 Hz Without ....