[siemens_summary]
[catalog_children]
[catalog_search_products]

Continuous gas analyzers ⍾ Page 49

Product detailsAdd to RFQ
7MB2041-1DA11-0AA1 - Siemens
Gas Analyzer OXYMAT 64, 19" unit for installation in cabinets ZrO2: Catalytically inactive cell (CIC) Low pressure, without suction pump (Atmosphere) Input: clamping ring connection 6 mm, output: Fittings 6 mm Gas monitoring: Flowmeter and limit switch (internal) AUTOCAL function with 8 additional digital inputs and outputs AC 100 to 120 V, 48 to 63 Hz Without . English
Product detailsAdd to RFQ
7MB2041-1DA11-1AA1-Z B03 - Siemens
Gas Analyzer OXYMAT 64, 19" unit for installation in cabinets ZrO2: Catalytically inactive cell (CIC) Low pressure, without suction pump (Atmosphere) Input: clamping ring connection 6 mm, output: Fittings 6 mm Gas monitoring: Flowmeter and limit switch (internal) AUTOCAL function with 8 additional digital inputs and outputs AC 200 to 240 V, 48 to 63 Hz Without . English TAG...
Product detailsAdd to RFQ
7MB2041-0DB10-1AA1 - Siemens
Gas Analyzer OXYMAT 64, 19" unit for installation in cabinets ZrO2: Catalytically active cell (CAC) Low pressure, without suction pump (Atmosphere) Input: clamping ring connection 1/4", output: Fittings 1/4" Gas monitoring: Flowmeter and limit switch (internal) Without AC 200 to 240 V, 48 to 63 Hz Without . English
Product detailsAdd to RFQ
7MB2041-1AA10-1AA1-Z Y11 - Siemens
Gas Analyzer OXYMAT 64, 19" unit for installation in cabinets ZrO2: Catalytically inactive cell (CIC) High pressure, without pressure regulator (2000 hPa) Input: clamping ring connection 6 mm, output: Fittings 6 mm Gas monitoring: Flowmeter and limit switch (internal) Without AC 200 to 240 V, 48 to 63 Hz Without . English Measuring range indication in plain text, if different...
Product detailsAdd to RFQ
7MB2041-0DA10-1AA1 - Siemens
Gas Analyzer OXYMAT 64, 19" unit for installation in cabinets ZrO2: Catalytically active cell (CAC) Low pressure, without suction pump (Atmosphere) Input: clamping ring connection 6 mm, output: Fittings 6 mm Gas monitoring: Flowmeter and limit switch (internal) Without AC 200 to 240 V, 48 to 63 Hz Without . English
Product detailsAdd to RFQ
7MB2041-1AB10-1AA1 - Siemens
Gas Analyzer OXYMAT 64, 19" unit for installation in cabinets ZrO2: Catalytically inactive cell (CIC) High pressure, without pressure regulator (2000 hPa) Input: clamping ring connection 1/4", output: Fittings 1/4" Gas monitoring: Flowmeter and limit switch (internal) Without AC 200 to 240 V, 48 to 63 Hz Without . English
Product detailsAdd to RFQ
7MB2041-0AA10-1AA1 - Siemens
Gas Analyzer OXYMAT 64, 19" unit for installation in cabinets ZrO2: Catalytically active cell (CAC) High pressure, without pressure regulator (2000 hPa) Input: clamping ring connection 6 mm, output: Fittings 6 mm Gas monitoring: Flowmeter and limit switch (internal) Without AC 200 to 240 V, 48 to 63 Hz Without . English
Product detailsAdd to RFQ
7MB2041-1AA10-1AA1 - Siemens
Gas Analyzer OXYMAT 64, 19" unit for installation in cabinets ZrO2: Catalytically inactive cell (CIC) High pressure, without pressure regulator (2000 hPa) Input: clamping ring connection 6 mm, output: Fittings 6 mm Gas monitoring: Flowmeter and limit switch (internal) Without AC 200 to 240 V, 48 to 63 Hz Without . English
Product detailsAdd to RFQ
7MB2041-1BA10-1AA0 - Siemens
Gas Analyzer OXYMAT 64, 19" unit for installation in cabinets Sensor: ZrO2: Catalytic inactive Cell (KIZ) Pressure of the measuring gas: high pressure, with pressure controler 2000 hPa to 6000 hPA Gas connections: inlet: clamping ring connection 3mm outlet: stub 6mm Gas monitoring: Flowmeter and limit switch (internal) Without additional electronics Power supply: AC 200 V to 240 V, 47...
Product detailsAdd to RFQ
7MB2041-1DA17-1AA1-Z B03 - Siemens
Gas Analyzer OXYMAT 64, 19" unit for installation in cabinets ZrO2: Catalytically inactive cell (CIC) Low pressure, without suction pump (Atmosphere) Input: clamping ring connection 6 mm, output: Fittings 6 mm Gas monitoring: Flowmeter and limit switch (internal) AUTOCAL function with 8 additional digital inputs/outputs and PROFIBUS DP interface AC 200 to 240 V, 48 to 63 Hz Without ....
Product detailsAdd to RFQ
7MB2024-0EA61-1BG0-Z A26 - Siemens
ULTRAMAT/OXYMAT 6 gas analyzer, 19" rack unit for installation in cabinets for combined measurement of IR absorbing gas and O2 Pipe with 6 mm outer diameter 5% reference gas pressure 3000 hPa Non-flow-type compensation branch: made of stainless steel, mat. No. 1.4571 Internal gas path (both channels): Stainless steel pipe (mat. No. 1.4571), sample chamber (lining, ULTRAMAT channel): Aluminium, reference...
Product detailsAdd to RFQ
7MB2024-0EA61-1BG1 - Siemens
ULTRAMAT/OXYMAT 6 gas analyzer, 19" rack unit for installation in cabinets for combined measurement of IR absorbing gas and O2 Pipe with 6 mm outer diameter 5% reference gas pressure 3000 hPa Non-flow-type compensation branch: made of stainless steel, mat. No. 1.4571 Internal gas path (both channels): Stainless steel pipe (mat. No. 1.4571), sample chamber (lining, ULTRAMAT channel): Aluminium, reference...