[siemens_summary]
[catalog_children]
[catalog_search_products]

IFM ⍾ Page 100

Product detailsAdd to RFQ
SV4204 - Ifm
Vortex flow meter with display; Operating voltage [V] : 18...30 DC; Min. insulation resistance [MΩ] : 100; (500 V DC); Protection class : III; Reverse polarity protection : yes; Power-on delay time [s] : < 3; Total number of outputs : 2; Output signal : analogue signal; Number of analogue outputs : 2; Analogue current output [mA] : 4...20; Max....
Product detailsAdd to RFQ
SV3150 - Ifm
Vortex flow meter; Operating voltage [V] : 8...33 DC; Min. insulation resistance [MΩ] : 100; (500 V DC); Protection class : III; Power-on delay time [s] : < 2; Total number of outputs : 1; Output signal : analogue signal; Number of analogue outputs : 1; Analogue current output [mA] : 4...20; (Q [l/min] = 0,625 x (I - 4...
Product detailsAdd to RFQ
SV4200 - Ifm
Vortex flow meter with display; Operating voltage [V] : 18...30 DC; Min. insulation resistance [MΩ] : 100; (500 V DC); Protection class : III; Reverse polarity protection : yes; Power-on delay time [s] : < 3; Total number of outputs : 2; Output signal : switching signal; frequency signal; IO-Link; (configurable); Electrical design : PNP/NPN; Number of digital outputs :...
Product detailsAdd to RFQ
SV4610 - Ifm
Vortex flow meter with display; Operating voltage [V] : 18...30 DC; Min. insulation resistance [MΩ] : 100; (500 V DC); Protection class : III; Reverse polarity protection : yes; Power-on delay time [s] : < 3; Total number of outputs : 2; Output signal : switching signal; frequency signal; IO-Link; (configurable); Electrical design : PNP/NPN; Number of digital outputs :...
Product detailsAdd to RFQ
SR5900 - Ifm
Control monitor for flow sensors; Operating voltage [V] : 19...36 DC; Protection class : III; Reverse polarity protection : yes; Power-on delay time [s] : 10; Number of channels : 1; Electrical design : PNP; Max. voltage drop switching output DC [V] : 2.5; Permanent current rating of switching output DC [mA] : 250; Switching function flow monitoring : output...
Product detailsAdd to RFQ
SV4504 - Ifm
Vortex flow meter with display; Operating voltage [V] : 18...30 DC; Min. insulation resistance [MΩ] : 100; (500 V DC); Protection class : III; Reverse polarity protection : yes; Power-on delay time [s] : < 3; Total number of outputs : 2; Output signal : analogue signal; Number of analogue outputs : 2; Analogue current output [mA] : 4...20; Max....
Product detailsAdd to RFQ
SR307A - Ifm
Control monitor for flow sensors; Operating voltage tolerance [%] : -15...15; Operating voltage [V] : 24 DC; Reverse polarity protection : no; Power-on delay time [s] : 10; Number of channels : 1; Performance in case of a fault : Relay de-energised in case of the following faults: wire break, reverse polarity or short circuit of the sensor cable, undervoltage,...
Product detailsAdd to RFQ
SV4050 - Ifm
Vortex flow meter; Operating voltage [V] : 8...33 DC; Min. insulation resistance [MΩ] : 100; (500 V DC); Protection class : III; Power-on delay time [s] : < 2; Total number of outputs : 1; Output signal : analogue signal; Number of analogue outputs : 1; Analogue current output [mA] : 4...20; (Q [l/min] = 0,938 x (I - 4...
Product detailsAdd to RFQ
SU8200 - Ifm
Ultrasonic flow meter; Operating voltage [V] : 19...30 DC; (according to EN 50178 SELV/PELV); Min. insulation resistance [MΩ] : 100; (500 V DC); Protection class : III; Reverse polarity protection : yes; Power-on delay time [s] : 10; Total number of outputs : 2; Output signal : switching signal; Electrical design : PNP; Number of digital outputs : 2; Output function...
Product detailsAdd to RFQ
SV4500 - Ifm
Vortex flow meter with display; Operating voltage [V] : 18...30 DC; Min. insulation resistance [MΩ] : 100; (500 V DC); Protection class : III; Reverse polarity protection : yes; Power-on delay time [s] : < 3; Total number of outputs : 2; Output signal : switching signal; frequency signal; IO-Link; (configurable); Electrical design : PNP/NPN; Number of digital outputs :...
Product detailsAdd to RFQ
SU9000 - Ifm
Ultrasonic flow meter; Operating voltage [V] : 19...30 DC; (according to EN 50178 SELV/PELV); Min. insulation resistance [MΩ] : 100; (500 V DC); Protection class : III; Reverse polarity protection : yes; Power-on delay time [s] : 10; Inputs : counter reset; Total number of outputs : 2; Output signal : switching signal; analogue signal; pulse signal; (configurable); Electrical design :...
Product detailsAdd to RFQ
SU7200 - Ifm
Ultrasonic flow meter; Operating voltage [V] : 19...30 DC; (according to EN 50178 SELV/PELV); Min. insulation resistance [MΩ] : 100; (500 V DC); Protection class : III; Reverse polarity protection : yes; Power-on delay time [s] : 10; Total number of outputs : 2; Output signal : switching signal; Electrical design : PNP; Number of digital outputs : 2; Output function...