[siemens_summary]
[catalog_children]
[catalog_search_products]

MAX48 ⍾ Page 2

Product detailsAdd to RFQ
MAX48N-32E7FCE0105 - Sick
Safety-related parameters: MTTFd: mean time to dangerous failure: 69 years (EN ISO 13849-1) 1) 2); Performance: Measured values: Positioning, speed; Measuring rangePosition (F.S.)0 mm ... 105 mm 1)Speed0 … 1,000 mm/s: Measuring range; Unusable rangeNull zone30 mmDamping zone63 mm: Unusable range; Switch-on time: < 250 ms; Measuring frequency (internal): 1 ms; Transmission rate (cycle time): CANopen (0 ... 65,535 ms),...
Product detailsAdd to RFQ
MAX48N-32V10MC0200 - Sick
Safety-related parameters: MTTFd: mean time to dangerous failure: 69 years (EN ISO 13849-1) 1) 2); Performance: Measured values: Positioning; Measuring rangePosition (F.S.)0 mm ... 200 mm 1): Measuring range; Unusable rangeNull zone30 mmDamping zone63 mm: Unusable range; Switch-on time: < 250 ms; Measuring frequency (internal): 2 ms; Transmission rate (cycle time): Constant analog output signal; Setpoint toleranceZero point and F.S.≤...
Product detailsAdd to RFQ
MAX48N-32V10K20500 - Sick
Safety-related parameters: MTTFd: mean time to dangerous failure: 69 years (EN ISO 13849-1) 1) 2); Performance: Measured values: Positioning; Measuring rangePosition (F.S.)0 mm ... 500 mm 1): Measuring range; Unusable rangeNull zone30 mmDamping zone63 mm: Unusable range; Switch-on time: < 250 ms; Measuring frequency (internal): 2 ms; Transmission rate (cycle time): Constant analog output signal; Setpoint toleranceZero point and F.S.≤...
Product detailsAdd to RFQ
MAX48N-32V10MC0500 - Sick
Safety-related parameters: MTTFd: mean time to dangerous failure: 69 years (EN ISO 13849-1) 1) 2); Performance: Measured values: Positioning; Measuring rangePosition (F.S.)0 mm ... 500 mm 1): Measuring range; Unusable rangeNull zone30 mmDamping zone63 mm: Unusable range; Switch-on time: < 250 ms; Measuring frequency (internal): 2 ms; Transmission rate (cycle time): Constant analog output signal; Setpoint toleranceZero point and F.S.≤...
Product detailsAdd to RFQ
MAX48N-32C7FCD2115 - Sick
Safety-related parameters: MTTFd: mean time to dangerous failure: 69 years (EN ISO 13849-1) 1) 2); Performance: Measured values: Positioning, speed; Measuring rangePosition (F.S.)0 mm ... 2,115 mm 1)Speed0 … 1,000 mm/s: Measuring range; Unusable rangeNull zone30 mmDamping zone63 mm: Unusable range; Switch-on time: < 250 ms; Measuring frequency (internal): 1 ms; Transmission rate (cycle time): CANopen (0 ... 65,535 ms),...
Product detailsAdd to RFQ
MAX48N-32C7FCP0310 - Sick
Safety-related parameters: MTTFd: mean time to dangerous failure: 69 years (EN ISO 13849-1) 1) 2); Performance: Measured values: Positioning, speed; Measuring rangePosition (F.S.)0 mm ... 310 mm 1)Speed0 … 1,000 mm/s: Measuring range; Unusable rangeNull zone30 mmDamping zone63 mm: Unusable range; Switch-on time: < 250 ms; Measuring frequency (internal): 1 ms; Transmission rate (cycle time): CANopen (0 ... 65,535 ms),...
Product detailsAdd to RFQ
MAX48N-32D3FDH0280 - Sick
Safety-related parameters: MTTFd: mean time to dangerous failure: 69 years (EN ISO 13849-1) 1) 2); Performance: Measured values: Positioning, speed; Measuring rangePosition (F.S.)0 mm ... 280 mm 1)Speed0 … 1,000 mm/s: Measuring range; Unusable rangeNull zone30 mmDamping zone63 mm: Unusable range; Switch-on time: < 250 ms; Measuring frequency (internal): 1 ms; Transmission rate (cycle time): CANopen (0 ... 65,535 ms),...
Product detailsAdd to RFQ
MAX48N-32A10MD0300 - Sick
Safety-related parameters: MTTFd: mean time to dangerous failure: 69 years (EN ISO 13849-1) 1) 2); Performance: Measured values: Positioning; Measuring rangePosition (F.S.)0 mm ... 300 mm 1): Measuring range; Unusable rangeNull zone30 mmDamping zone63 mm: Unusable range; Switch-on time: < 250 ms; Measuring frequency (internal): 2 ms; Transmission rate (cycle time): Constant analog output signal; Setpoint toleranceZero point and F.S.≤...
Product detailsAdd to RFQ
MAX48N-32A10MC0800 - Sick
Safety-related parameters: MTTFd: mean time to dangerous failure: 69 years (EN ISO 13849-1) 1) 2); Performance: Measured values: Positioning; Measuring rangePosition (F.S.)0 mm ... 800 mm 1): Measuring range; Unusable rangeNull zone30 mmDamping zone63 mm: Unusable range; Switch-on time: < 250 ms; Measuring frequency (internal): 2 ms; Transmission rate (cycle time): Constant analog output signal; Setpoint toleranceZero point and F.S.≤...
Product detailsAdd to RFQ
MAX48N-32A10MC0500 - Sick
Safety-related parameters: MTTFd: mean time to dangerous failure: 69 years (EN ISO 13849-1) 1) 2); Performance: Measured values: Positioning; Measuring rangePosition (F.S.)0 mm ... 500 mm 1): Measuring range; Unusable rangeNull zone30 mmDamping zone63 mm: Unusable range; Switch-on time: < 250 ms; Measuring frequency (internal): 2 ms; Transmission rate (cycle time): Constant analog output signal; Setpoint toleranceZero point and F.S.≤...
Product detailsAdd to RFQ
MAX48N-32C7FCP1375 - Sick
Safety-related parameters: MTTFd: mean time to dangerous failure: 69 years (EN ISO 13849-1) 1) 2); Performance: Measured values: Positioning, speed; Measuring rangePosition (F.S.)0 mm ... 1,375 mm 1)Speed0 … 1,000 mm/s: Measuring range; Unusable rangeNull zone30 mmDamping zone63 mm: Unusable range; Switch-on time: < 250 ms; Measuring frequency (internal): 1 ms; Transmission rate (cycle time): CANopen (0 ... 65,535 ms),...
Product detailsAdd to RFQ
MAX48N-32A10MC1200 - Sick
Safety-related parameters: MTTFd: mean time to dangerous failure: 69 years (EN ISO 13849-1) 1) 2); Performance: Measured values: Positioning; Measuring rangePosition (F.S.)0 mm ... 1,200 mm 1): Measuring range; Unusable rangeNull zone30 mmDamping zone63 mm: Unusable range; Switch-on time: < 250 ms; Measuring frequency (internal): 2 ms; Transmission rate (cycle time): Constant analog output signal; Setpoint toleranceZero point and F.S.≤...