[siemens_summary]
[catalog_children]
[catalog_search_products]

Process sensors ⍾ Page 38

Product detailsAdd to RFQ
SD2001 - Ifm
Compressed air meter; Operating voltage [V] : 19...30 DC; (according to EN 50178 SELV/PELV); Protection class : III; Reverse polarity protection : yes; Power-on delay time [s] : 0.5; Total number of outputs : 2; Output signal : switching signal; analogue signal; pulse signal; (configurable); Electrical design : PNP; Number of digital outputs : 2; Output function : normally open /...
Product detailsAdd to RFQ
SD5000 - Ifm
Compressed air meter; Operating voltage [V] : 18...30 DC; (according to EN 50178 SELV/PELV); Protection class : III; Reverse polarity protection : yes; Power-on delay time [s] : 1; Total number of outputs : 2; Output signal : switching signal; analogue signal; pulse signal; IO-Link; (configurable); Electrical design : PNP; Number of digital outputs : 2; Output function : normally open...
Product detailsAdd to RFQ
SF121A - Ifm
Flow sensor for connection to an evaluation unit; Response time [s] : 1...10; Connection to control monitor : VS2000 Exi (PTB 01 ATEX 2075); Probe length L [mm] : 12; Temperature gradient [K/min] : 15; Ambient temperature [°C] : -20...70; Max. internal capacitance [nF] : 1.2; Max. internal inductance [µH] : 6; Temperature class : T4; Housing : threaded type;...
Product detailsAdd to RFQ
SD2000 - Ifm
Compressed air meter; Operating voltage [V] : 18...30 DC; (according to EN 50178 SELV/PELV); Protection class : III; Reverse polarity protection : yes; Power-on delay time [s] : 1; Total number of outputs : 2; Output signal : switching signal; analogue signal; pulse signal; IO-Link; (configurable); Electrical design : PNP; Number of digital outputs : 2; Output function : normally open...
Product detailsAdd to RFQ
SF120A - Ifm
Flow sensor for connection to an evaluation unit; Response time [s] : 1...10; Connection to control monitor : VS2000 Exi (PTB 01 ATEX 2075); Probe length L [mm] : 12; Temperature gradient [K/min] : 15; Ambient temperature [°C] : -20...70; Max. internal capacitance [nF] : 0.4; Max. internal inductance [µH] : 2; Temperature class : T4; Housing : threaded type;...
Product detailsAdd to RFQ
SDG100 - Ifm
Compressed air meter; Operating voltage [V] : 19...30 DC; Protection class : III; Reverse polarity protection : yes; Power-on delay time [s] : 0.5; Total number of outputs : 2; Output signal : switching signal; analogue signal; pulse signal; (configurable); Electrical design : PNP; Number of digital outputs : 2; Output function : normally open / normally closed; (parameterisable); Max....
Product detailsAdd to RFQ
SF111A - Ifm
Flow sensor for connection to an evaluation unit; Response time [s] : 1...10; Connection to control monitor : VS2000 Exi (PTB 01 ATEX 2075); Probe length L [mm] : 12; Temperature gradient [K/min] : 15; Ambient temperature [°C] : -20...60; Housing : threaded type; Thread designation : M12 x 1; Materials : stainless steel (1.4404 / 316L); Materials (wetted parts)...
Product detailsAdd to RFQ
SDG150 - Ifm
Compressed air meter; Operating voltage [V] : 19...30 DC; Protection class : III; Reverse polarity protection : yes; Power-on delay time [s] : 0.5; Total number of outputs : 2; Output signal : switching signal; analogue signal; pulse signal; (configurable); Electrical design : PNP; Number of digital outputs : 2; Output function : normally open / normally closed; (parameterisable); Max....
Product detailsAdd to RFQ
SDG107 - Ifm
Compressed air meter; Operating voltage [V] : 19...30 DC; Protection class : III; Reverse polarity protection : yes; Power-on delay time [s] : 0.5; Total number of outputs : 2; Output signal : switching signal; analogue signal; pulse signal; (configurable); Electrical design : PNP; Number of digital outputs : 2; Output function : normally open / normally closed; (parameterisable); Max....
Product detailsAdd to RFQ
SD6101 - Ifm
Flow rate meter for gases; Measuring range : 15...4310 scfh: 0.2...71.8 scfm: 2...552 sfs; Display range : 0...5170 scfh: 0...86.2 scfm: 0...663 sfs; Resolution : 5 scfh: 0.1 scfm: 1 sfs; Set point SP : 40...4310 scfh: 0.7...71.8 scfm: 5...552 sfs; Reset point rP : 20...4290 scfh: 0.4...71.5 scfm: 3...550 sfs; Analogue start point ASP : 0...3445 scfh: 0...57.4 scfm:...
Product detailsAdd to RFQ
SD8001 - Ifm
Compressed air meter; Operating voltage [V] : 19...30 DC; (according to EN 50178 SELV/PELV); Protection class : III; Reverse polarity protection : yes; Power-on delay time [s] : 0.5; Total number of outputs : 2; Output signal : switching signal; analogue signal; pulse signal; (configurable); Electrical design : PNP; Number of digital outputs : 2; Output function : normally open /...
Product detailsAdd to RFQ
SD6050 - Ifm
Compressed air meter; Operating voltage [V] : 18...30 DC; (according to EN 50178 SELV/PELV); Protection class : III; Reverse polarity protection : yes; Power-on delay time [s] : 1; Total number of outputs : 2; Output signal : switching signal; analogue signal; pulse signal; IO-Link; (configurable); Electrical design : PNP; Number of digital outputs : 2; Output function : normally open...