[siemens_summary]
[catalog_children]
[catalog_search_products]

Process sensors ⍾ Page 38

Product detailsAdd to RFQ
SF111A - Ifm
Flow sensor for connection to an evaluation unit; Response time [s] : 1...10; Connection to control monitor : VS2000 Exi (PTB 01 ATEX 2075); Probe length L [mm] : 12; Temperature gradient [K/min] : 15; Ambient temperature [°C] : -20...60; Housing : threaded type; Thread designation : M12 x 1; Materials : stainless steel (1.4404 / 316L); Materials (wetted parts)...
Product detailsAdd to RFQ
SDG150 - Ifm
Compressed air meter; Operating voltage [V] : 19...30 DC; Protection class : III; Reverse polarity protection : yes; Power-on delay time [s] : 0.5; Total number of outputs : 2; Output signal : switching signal; analogue signal; pulse signal; (configurable); Electrical design : PNP; Number of digital outputs : 2; Output function : normally open / normally closed; (parameterisable); Max....
Product detailsAdd to RFQ
SDG107 - Ifm
Compressed air meter; Operating voltage [V] : 19...30 DC; Protection class : III; Reverse polarity protection : yes; Power-on delay time [s] : 0.5; Total number of outputs : 2; Output signal : switching signal; analogue signal; pulse signal; (configurable); Electrical design : PNP; Number of digital outputs : 2; Output function : normally open / normally closed; (parameterisable); Max....
Product detailsAdd to RFQ
SDG152 - Ifm
Compressed air meter; Operating voltage [V] : 19...30 DC; Protection class : III; Reverse polarity protection : yes; Power-on delay time [s] : 0.5; Total number of outputs : 2; Output signal : switching signal; analogue signal; pulse signal; (configurable); Electrical design : PNP; Number of digital outputs : 2; Output function : normally open / normally closed; (parameterisable); Max....
Product detailsAdd to RFQ
SDG102 - Ifm
Compressed air meter; Operating voltage [V] : 19...30 DC; Protection class : III; Reverse polarity protection : yes; Power-on delay time [s] : 0.5; Total number of outputs : 2; Output signal : switching signal; analogue signal; pulse signal; (configurable); Electrical design : PNP; Number of digital outputs : 2; Output function : normally open / normally closed; (parameterisable); Max....
Product detailsAdd to RFQ
SDG157 - Ifm
Compressed air meter; Operating voltage [V] : 19...30 DC; Protection class : III; Reverse polarity protection : yes; Power-on delay time [s] : 0.5; Total number of outputs : 2; Output signal : switching signal; analogue signal; pulse signal; (configurable); Electrical design : PNP; Number of digital outputs : 2; Output function : normally open / normally closed; (parameterisable); Max....
Product detailsAdd to RFQ
SDG087 - Ifm
Compressed air meter; Operating voltage [V] : 19...30 DC; Protection class : III; Reverse polarity protection : yes; Power-on delay time [s] : 0.5; Total number of outputs : 2; Output signal : switching signal; analogue signal; pulse signal; (configurable); Electrical design : PNP; Number of digital outputs : 2; Output function : normally open / normally closed; (parameterisable); Max....
Product detailsAdd to RFQ
SDG080 - Ifm
Compressed air meter; Operating voltage [V] : 19...30 DC; Protection class : III; Reverse polarity protection : yes; Power-on delay time [s] : 0.5; Total number of outputs : 2; Output signal : switching signal; analogue signal; pulse signal; (configurable); Electrical design : PNP; Number of digital outputs : 2; Output function : normally open / normally closed; (parameterisable); Max....
Product detailsAdd to RFQ
SDG082 - Ifm
Compressed air meter; Operating voltage [V] : 19...30 DC; Protection class : III; Reverse polarity protection : yes; Power-on delay time [s] : 0.5; Total number of outputs : 2; Output signal : switching signal; analogue signal; pulse signal; (configurable); Electrical design : PNP; Number of digital outputs : 2; Output function : normally open / normally closed; (parameterisable); Max....
Product detailsAdd to RFQ
SC050R - Ifm
Flow monitor
Product detailsAdd to RFQ
SBY432 - Ifm
Flow transmitter with integrated backflow prevention; Operating voltage [V] : 18...32 DC; (to SELV/PELV); Protection class : III; Reverse polarity protection : yes; Output signal : analogue signal; Analogue current output [mA] : 4...20; Max. load [Ω] : 500; Short-circuit protection : yes; Overload protection : yes; Measuring range [l/min] : 0.3...15; Repeatability [% of the final value] : 1;...
Product detailsAdd to RFQ
SBY457 - Ifm
Flow transmitter with integrated backflow prevention; Operating voltage [V] : 18...32 DC; (to SELV/PELV); Protection class : III; Reverse polarity protection : yes; Output signal : analogue signal; Analogue current output [mA] : 4...20; Max. load [Ω] : 500; Short-circuit protection : yes; Overload protection : yes; Measuring range [l/min] : 8...200; Repeatability [% of the final value] : 1;...