[siemens_summary]
[catalog_children]
[catalog_search_products]

Process sensors ⍾ Page 40

Product detailsAdd to RFQ
SD6050 - Ifm
Compressed air meter; Operating voltage [V] : 18...30 DC; (according to EN 50178 SELV/PELV); Protection class : III; Reverse polarity protection : yes; Power-on delay time [s] : 1; Total number of outputs : 2; Output signal : switching signal; analogue signal; pulse signal; IO-Link; (configurable); Electrical design : PNP; Number of digital outputs : 2; Output function : normally open...
Product detailsAdd to RFQ
SD6100 - Ifm
Flow rate meter for gases; Measuring range [m³/h] : 0.4...122; Display range [m³/h] : 0...146.4; Resolution [m³/h] : 0.1; Set point SP [m³/h] : 1.1...122; Reset point rP [m³/h] : 0.6...121.5; Analogue start point ASP [m³/h] : 0...97.6; Analogue end point AEP [m³/h] : 24.4...122; In steps of [m³/h] : 0.1; Measuring range [m³/h] : 0.2...74.7; Display range [m³/h] :...
Product detailsAdd to RFQ
SD6001 - Ifm
Compressed air meter; Operating voltage [V] : 19...30 DC; (according to EN 50178 SELV/PELV); Protection class : III; Reverse polarity protection : yes; Power-on delay time [s] : 1; Total number of outputs : 2; Output signal : switching signal; analogue signal; pulse signal; (configurable); Electrical design : PNP; Number of digital outputs : 2; Output function : normally open /...
Product detailsAdd to RFQ
SD8000 - Ifm
Compressed air meter; Operating voltage [V] : 18...30 DC; (according to EN 50178 SELV/PELV); Protection class : III; Reverse polarity protection : yes; Power-on delay time [s] : 1; Total number of outputs : 2; Output signal : switching signal; analogue signal; pulse signal; IO-Link; (configurable); Electrical design : PNP; Number of digital outputs : 2; Output function : normally open...
Product detailsAdd to RFQ
SBN434 - Ifm
Flow transmitter with integrated backflow prevention; Operating voltage [V] : 18...32 DC; (to SELV/PELV); Protection class : III; Reverse polarity protection : yes; Output signal : analogue signal; Analogue current output [mA] : 4...20; Max. load [Ω] : 500; Short-circuit protection : yes; Overload protection : yes; Measuring range [gpm] : 0.2...10; Repeatability [% of the final value] : 1;...
Product detailsAdd to RFQ
SBN446 - Ifm
Flow transmitter with integrated backflow prevention; Operating voltage [V] : 18...32 DC; (to SELV/PELV); Protection class : III; Reverse polarity protection : yes; Output signal : analogue signal; Analogue current output [mA] : 4...20; Max. load [Ω] : 500; Short-circuit protection : yes; Overload protection : yes; Measuring range [gpm] : 0.5...27; Repeatability [% of the final value] : 1;...
Product detailsAdd to RFQ
SBN433 - Ifm
Flow transmitter with integrated backflow prevention; Operating voltage [V] : 18...32 DC; (to SELV/PELV); Protection class : III; Reverse polarity protection : yes; Output signal : analogue signal; Analogue current output [mA] : 4...20; Max. load [Ω] : 500; Short-circuit protection : yes; Overload protection : yes; Measuring range [gpm] : 0.2...6; Repeatability [% of the final value] : 1;...
Product detailsAdd to RFQ
SBU924 - Ifm
Flow transmitter with integrated backflow prevention; Operating voltage tolerance [%] : -15...10; Operating voltage [V] : 24 DC; (to SELV/PELV); Protection class : III; Reverse polarity protection : yes; Output signal : analogue signal; Analogue voltage output [V] : 0.5...10; Min. load resistance [Ω] : 10000; Short-circuit protection : yes; Overload protection : yes; Measuring range [l/min] : 2...50; Flow...
Product detailsAdd to RFQ
SBY232 - Ifm
Flow meter with integrated backflow prevention and display; Operating voltage [V] : 18...30 DC; (according to EN 50178 SELV/PELV); Protection class : III; Reverse polarity protection : yes; Power-on delay time [s] : 1 l/min); Response time [s] : 0.01; Damping for the switching output dAP [s] : 0...5; Damping for the analogue output dAA [s] : 0...5; Parameter setting options...
Product detailsAdd to RFQ
SBY321 - Ifm
Flow sensor with integrated backflow prevention; Operating voltage [V] : 10...30 DC; (to SELV/PELV); Protection class : III; Reverse polarity protection : yes; Total number of outputs : 1; Output signal : switching signal; Electrical design : PNP; Number of digital outputs : 1; Output function : normally open; Max. voltage drop switching output DC [V] : 2.5; Permanent current...
Product detailsAdd to RFQ
SBY246 - Ifm
Flow meter with integrated backflow prevention and display; Operating voltage [V] : 18...30 DC; (according to EN 50178 SELV/PELV); Protection class : III; Reverse polarity protection : yes; Power-on delay time [s] : 1 l/min); Response time [s] : 0.01; Damping for the switching output dAP [s] : 0...5; Damping for the analogue output dAA [s] : 0...5; Parameter setting options...
Product detailsAdd to RFQ
SBY233 - Ifm
Flow meter with integrated backflow prevention and display; Operating voltage [V] : 18...30 DC; (according to EN 50178 SELV/PELV); Protection class : III; Reverse polarity protection : yes; Power-on delay time [s] : 1 l/min); Response time [s] : 0.01; Damping for the switching output dAP [s] : 0...5; Damping for the analogue output dAA [s] : 0...5; Parameter setting options...